Filter Results By:

Products

Applications

Manufacturers

Showing results: 166 - 174 of 174 items found.

  • Spectrum Analysis

    S95090B - Keysight Technologies

    The S95090B spectrum analyzer (SA) measurement software adds high-performance microwave spectrum analysis to PXI VNAs. With fast stepped-FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The S95090B software uses the PXI network analyzer's test and reference receivers to complete simultaneous spectrum measurements. Multi-channel SA measurements leverage the PXI VNA's internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The S95090B spectrum analyzer software application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy. Optional external attenuators should be connected with the VNA’s test ports to avoid receiver compression when measuring large signals.

  • Multifrequency Clock Synthesizer - PMC

    Model 7190 - Pentek, Inc.

    - Simultaneous synthesis of up to 5 different clocks- 8 SMC clock outputs- Ideal for A/D and D/A converter clock sources- Typical phase noise: -125 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 or 10 MHz- Four quad VCXOs allow selection from 16 different base frequencies- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 500 MHz- Control and status via PCI bus interface

  • VLSI Test Systems

    Chroma ATE Inc.

    50/100 MHz clock rate50/100 Mbps data rate1024 I/O pins (Max :1280 I/O pins)Up to 1024 sites Parallel testing32/64 M pattern memoryVarious VI sourceFlexible HW-architecture (Interchangeable I/O, VI, ADDA,)Real parallel trim/match functionTime & frequency measurement unit (TFMU)High-speed time measurement unit (HSTMU)AD/DA test optionSCAN test option (max 1G M/chain)ALPG test option for embedded memorySTDF tools supportTest program/pattern converter(J750, D10, V50, E320, SC312, V7, TRI-6020, ITS9K)User friendly windows 7 environmentCRAFT C/C++ programming languageSW (Software) same as 3380P & 3360P

  • Three Phase Power Analyzer

    Model PA-600 - Gopal Electronics

    Power Analyzer Model PA-600 is having advanced measurement capability which gives accurate measurement also at low power factor such as 0.1PF with 0.1% basic accuracy. 16 bit microcontroller and 24bit Analog to digital converter performs accurate measurement & calculation of Voltage, current, power, power factor, crest factor, form factor and frequency with any load and signals of frequencies from 30 Hz to 800 Hz. PA600 is most applicable for no load and full load testing of distribution and power transformer. You can read true RMS value, peak value, mean value and average value of any parameter simultaneously in LCD display.

  • Electrical Calibration

    GF6018A - Beijing GFUVE Electronics Co.,Ltd.

    The equipment is compliance with national verification regulation: JJG1242005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.

  • IRIG Time Code Receiver & Generator Module

    TCR180 - Meinberg Funkuhren GmbH & Co. KG

    The module TCR180 has been designed to receive and to generate IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements) or as an IRIG converter device. The frequency locking of the master oscillator to the time code system enables this module to generate fixed and programmable standard frequencies with high accuracy and stability. Various oscillator options allow the cost efficient implementation of different requirements concerning the accurracy of the outputs. The generator of the IMS-TCR module generates pulses per second and per minute and per hour. Four programmable outputs are also available. The pulses are synchronized to UTC-second.

  • Qualification and Quality Control Tests

    Techsquare - Techimp HQ S.r.L

    New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • 20 GHz Signal Source

    VCO Series - SignalCore, Inc.

    The SC5510A and SC5511A are VCO-based, synthesized signal sources with very low phase noise and an amplitude control of 0.01 dB throughout its -30 dBm to +15 dBm output power range. By utilizing a unique multiple phase-locked loop architecture, phase spurs are kept below -70 dBc across the entire tuning range, even at 1 Hz step resolution. Download the data sheet to see how the impressive features and specifications of these modules make them stand out when compared to other small modular synthesizers. These 20 GHz signal sources include an additional, independent RF2 channel with a tunable frequency range from 100 MHz to 3 GHz and a tuning resolution of 25 MHz. The extra channel makes the modules suitable for either single-stage RF conversion systems or dual-stage image suppression up/down converter systems. Both modules make great general-purpose laboratory signal sources where demanding low phase noise and signal purity are required. They are both ideal choices as an integrated clock source for fast DAC and ADC applications, especially those that require variable sampling rates. Full implementation instructions, GUI, driver software, and example code are provided with each module.

Get Help